GSMCentrum.CZ » Measuring instruments » Multimeters, measuring instruments » Multimeters » Digital Multimeters
| Barcode: | |
| Number: | TMEFLK-87VMAX-E2KIT |
| Package: | |
| Min. quantity: | 1 |
| Items in stock i | 5 pieces |
|---|---|
| Manufacturer: | FLUKE |
Digitandl multimeter LCD (6000/20000),with and bandcklit 0.01÷60S - Popis produktu
| Manufacturer | FLUKE |
|---|---|
| Type of meter | digital multimeter |
| Measurement | AC current |
| Measurement | AC voltage |
| Measurement | capacitance |
| Measurement | DC current |
| Measurement | DC voltage |
| Measurement | frequency |
| Measurement | resistance |
| Measurement | temperature |
| Kind of display used | LCD (6000/20000) |
| Kind of display used | with a backlit |
| Bargraph | 33 segm. 40x/s |
| DC voltage measuring range | 0.1...600mV |
| DC voltage measuring range | 6V |
| DC voltage measuring range | 60V |
| DC voltage measuring range | 600V |
| DC voltage measuring range | 1kV |
| DC voltage measuring accuracy | ±(0,05% + 1 digit) |
| AC voltage measuring range | 0.1...600mV |
| AC voltage measuring range | 6V |
| AC voltage measuring range | 60V |
| AC voltage measuring range | 600V |
| AC voltage measuring range | 1kV |
| AC voltage measuring accuracy | ±(0,7% + 4 digits) |
| DC current measuring range | 0.1...600µA |
| DC current measuring range | 6000µA |
| DC current measuring range | 60mA |
| DC current measuring range | 400mA |
| DC current measuring range | 6A |
| DC current measuring range | 10A |
| DC current measuring range | 20A < 30s |
| AC current measuring range | 0.1...600µA |
| AC current measuring range | 6000µA |
| AC current measuring range | 60mA |
| AC current measuring range | 400mA |
| AC current measuring range | 6A |
| AC current measuring range | 10A |
| AC current measuring range | (20A <30s) |
| DC current measuring accuracy | ±(0,2% + 4 digits) |
| AC current measuring accuracy | ±(1% + 2 digits) |
| True effective value measurement | True RMS AC |
| Resistance measuring range | 100mΩ...600Ω |
| Resistance measuring range | 6kΩ |
| Resistance measuring range | 60kΩ |
| Resistance measuring range | 600kΩ |
| Resistance measuring range | 6MΩ |
| Resistance measuring range | 50MΩ |
| Resistance measuring accuracy | ±(0,2% + 1 digit) |
| Capacitance measuring range | 0.01...10nF |
| Capacitance measuring range | 100nF |
| Capacitance measuring range | 1µF |
| Capacitance measuring range | 10µF |
| Capacitance measuring range | 100µF |
| Capacitance measuring range | 9999µF |
| Capacitance measuring accuracy | ±(1% + 2 digits) |
| Frequency measuring range | 10mHz...199.99Hz |
| Frequency measuring range | 1999.9Hz |
| Frequency measuring range | 19.999kHz |
| Frequency measuring range | 199.99kHz |
| Frequency measuring accuracy | ±(0,005% + 1 digit) |
| Temperature measuring range | -200...1090°C |
| Temperature measurement accuracy | ±(1% + 10 digits) |
| Temperature measurement resolution | 0.1°C |
| Conductance measurement | 0.01...60S |
| Conductance measuring accuracy | ±(1% + 10 digits) |
| Diode test | 1mA @3V |
| Continuity test | acoustic indication |
| Pollution degree | 2 |
| IP rating | IP67 |
| Weight with battery | 700g |
| Power supply | 3 batteries 1,5V LR6 (AA) |
| Standard equipment | 2x crocodile clip FLK-AC220 |
| Standard equipment | batteries |
| Standard equipment | FLK-80BK-A drop-like K-type temperature probe |
| Standard equipment | FLK-C35 soft cover |
| Standard equipment | FLK-TL238 test probes |
| Standard equipment | magnetic hanging strap FLK-TOOLPAK |
| Standard equipment | test leads FLK-TL-224 |
| Optional equipment | 400A AC/DC FLK-I410 current clamp probe |
| Optional equipment | FLK-C25 soft cover |
| Optional equipment | FLK-TL238 set |
| Optional equipment | FLK-TOOLPAK strap with magnet for suspending the meter |
| Conform to the norm | EN61010 600V CAT IV |
| Conform to the norm | EN61010 1000V CAT III |
| Related items | POM-4408 |
| Related items | POM-5519A |
| Related items | POM-5673B |
| Dimensions (W x H x D) | 63x198x100mm |
| Measuring instruments application | FLK-80BK-A |
| Measuring instruments application | FLK-80PJ-1 |
| Measuring instruments application | FLK-80PJ-9 |
| Measuring instruments application | FLK-80PJ-EXT |
| Measuring instruments application | FLK-80PK-1 |
| Measuring instruments application | FLK-80PK-3A |
| Measuring instruments application | FLK-80PK-8 |
| Measuring instruments application | FLK-80PK-9 |
| Measuring instruments application | FLK-80PK-11 |
| Measuring instruments application | FLK-80PK-22 |
| Measuring instruments application | FLK-80PK-24 |
| Measuring instruments application | FLK-80PK-25 |
| Measuring instruments application | FLK-80PK-26 |
| Measuring instruments application | FLK-80PK-27 |
| Measuring instruments application | FLK-80PR-60 |
| Measuring instruments application | FLK-80PT-EXT |
| Measuring instruments application | FLK-80T-150UA |
| Measuring instrument features | auto and manual ranging |
| Measuring instrument features | automatic power-off |
| Measuring instrument features | built-in thermometer |
| Measuring instrument features | filter ensuring voltage and frequency measuring accuracy |
| Measuring instrument features | HOLD function |
| Measuring instrument features | impact resistant holster |
| Measuring instrument features | indicates incorrect connection of test leads |
| Measuring instrument features | MIN/MAX/MEDIUM function |
| Measuring instrument features | PEAK HOLD function |
| Measuring instrument features | test leads resistance compensation |